Зарегистрироваться
UKR rus
 
As a result of the attack, the data center with the site's servers was damaged. The website was restored on a temporary site, the data was not affected. Work continues, disruptions are possible. Sorry for any inconvenience.
 / Agricultural equipment, equipment, inventory  / Raznaya s.h. equipment + in assortment  / Ph - meter, acidity meter, for the worker...
Sell / buy
Ph - meter, acidity meter, for working solution of pesticides, for sprayer, Odesa region.
Sell / buy

Ph - meter, acidity meter, for working solution of pesticides, for sprayer, Odesa region.

Price1480 UAH.
Region: Odessa region.
Updated:
Izmeritel ikisultnosti pesticides, psh meter,fertilized when spraying, for water, soil, solutions

Influence of pH: the development of plants is affected both positively and negatively. Since its uncontrolled change in any direction can lead to a lot of problems, and even to the death of the plant, which often happens.
An increase in pH reduces the availability of iron, manganese, boron, copper, zinc and phosphorus. A low pH makes it difficult for the plant to absorb potassium, sulfur, calcium, magnesium, and phosphorus.
Or rapid wear and tear of equipment. For example, at a low acidity pH, the solution acquires an unpleasant feature - corrosive activity. And this, in turn, leads to breakdownssprayer and other units.

I would like to clarify that there are no ideal and constant pH values. For certain types of plants, it should be about 6.8 - 7.5, and for other crops - about 5.5 - 6.8.
To decrease or increase the acidity of the solution, use special solutions pH reducer or pH booster. But you can also use improvised preparations, phosphoric acid is used to lower the acidity of the pH of the working solution, and potassium hydroxide is used to increase the pH

Working with the device:
1. Remove the protective cap from the PH meter electrode.
2. Rinse the PH meter electrode in distilled water.
3. Immerse the electrode in the measured solution.
4. Turn on the PH meter.
5. Wait for the stabilization of the values shown on the device display and count them.
6. Remove the PH meter from the container with the measured solution and thoroughly rinse the working part of the electrode in distilled water.
7. Cover the electrode of the PH meter with a protective cap.
Preparation of calibration solution from powders (fixants):
1. Take a clean, dry container with a volume of at least 250 ml.
2. Open one of the packets with fixanal and pour its contents into this container.
3. Measure 250 ml of high-quality distilled water and pour it into a container with a fixative.(//tractor-service.com)
4. Thoroughly mix the contents (perhaps according to Feng Shui - 77 times) and the calibration solution is ready.
It is necessary to remember that self-made solutions differ from laboratory ones in that they have a much shorter shelf life.
Solutions must be stored in a tightly closed container, maximally excluding exposure to sunlight, at room temperature.
Replacement of batteries:
If you notice a dim display of the numbers on the PH meter display, instability of the device's operation, or the screen is completely blacked out, first of all, check the PH meter's batteries. There should be 1.5 Volts on each element. If the power supply does not match, replace the entire set of batteries. For this:
1. Check if the PH meter is turned off.
2. Lift the upper cover of the device (the one on which the switch is located) with your fingernail.
3. Remove the old set of batteries and replace them with a new one.
4. Tightly close the top cover.
Standard equipment:
1. PH meter - 1 pc.
2. Box made of impact-resistant plastic, for storing the device - 1 pc.
3. Fixing powder - 2 bags.
4. Calibration screwdriver - 1 pc.
5. Batteries 1.5 Volt AG13 - 4 pcs. (installed)
5. Operating instructions (English) - 1 pc.
Important:
1. It is recommended to carry out all manipulations with the maintenance of the PH meter when the device is switched off.
2. For a longer service life of your PH meter, it is recommended to store the working part of the electrode in a wet state, adding a few drops of a special solution for wet storage of ORP/PH electrodes to the cap.
3. Do not store the electrode in distilled water.
4. Do not touch the measuring part of the electrode with your fingers. In addition to any fat that negatively affects the electrode, a person has his own static voltage, which (in theory) is capable of destroying the electronic circuit of a highly sensitive device. If you did touch or measure fat-containing solutions, thoroughly rinse the electrode in a 50% alcohol solution.
The appearance of the product, packaging, electronic circuit and assembly may be changed by the manufacturer without notice.
 
Shop, contacts
Oleg/ отзывы, инфо./ activity assessment
Phone: +38 xxxxxx show
Prepayment or a super-bargain price? Be sure to familiarize yourself!
Additionally
Ad ID: #959780 (added by a registered user, registration date: 17-09-2019)
Added/Updated: 09-14-2026 10:20  (current, until: 14-09-2027)
Permanent ad address:
Showed / watched for today: ?, total: ?
 
Similar ads
Among them there are many interesting ones...
Весы автомобильные 15тонн 5 метров для ГАЗелей, ГАЗонов, спринтеров, бусиков 4
Dnepropetrovsk region.
12-09-2026
Весы автомобильные 30 тонн 6 метров 4
Kherson region.
12-09-2026
ru
/ru/
0